45° Eccentric Flaring Tool, Six Sizes
Our Price:$159.94This 45° eccentric flaring tool is designed for HVAC/R technicians who need to form tubing flares during installation and service work. It supports six tubing sizes to help technicians prepare...
-
45° Flaring and Swaging Tool Set
Our Price:$119.94This 45° flaring and swaging tool set is for HVAC technicians and maintenance professionals working with tubing. It helps create flares and swages, including in close quarters where punch-style tools...
-
45° Flaring and Tube Cutting Tool Set
Our Price:$105.94This 45° flaring and tube cutting tool set is for HVAC technicians and maintenance professionals who need to cut tubing and create 45° flares during installation or service work. It combines the...
-
5 Amp Fuse Tester with Light
Our Price:$15.49This 5 amp fuse tester is for HVAC technicians servicing furnaces, boilers, air handlers, and other systems with a fused printed circuit board. It plugs into the board to help test low-voltage...
-
5 MFD 440V Oval Run Capacitor
Our Price:$3.47This 5 MFD, 440V oval run capacitor is for HVAC technicians and maintenance professionals servicing motor-run applications. It provides the electrical capacitance needed to support compatible...
-
5 MFD Round Run Capacitor, 370/440V
Our Price:$11.99This round run capacitor is for HVAC service professionals replacing a 5 MFD capacitor in compatible equipment. It provides the electrical capacitance needed for run-capacitor service at 370/440V.The...
-
5/8-Inch Shaft Thrust Collars, 12-Pack
Our Price:$16.49These thrust collars are for maintenance professionals working with trucks, generators, construction machinery, and similar equipment. They provide a collar option for 5/8-inch shaft applications...
-
5/8-Inch Shaft Thrust Collars, 2-Pack
Our Price:$29.94These thrust collars are designed for buyers servicing equipment with 5/8-inch shafts, including trucks, generators, and construction machinery. They help support shaft-related assembly and...
-
50 + 7.5 MFD 440V Round Run Capacitor
Our Price:$13.74This round motor-run capacitor is for HVAC technicians and maintenance professionals servicing compatible equipment. It provides 50 + 7.5 MFD capacitance at 440V to support motor operation.The...
-
50 MFD 440V Oval Motor Run Capacitor
Our Price:$12.49This oval motor run capacitor is for HVAC service professionals and maintenance teams replacing a compatible motor capacitor. Its 50 MFD and 440V ratings support motor operation in compatible...
-
55 + 7.5 MFD 440V Round Run Capacitor
Our Price:$14.99This round run capacitor is an HVAC electrical replacement component for technicians and maintenance professionals. It provides 55 + 7.5 MFD capacitance at 440V for compatible motor-run applications...
-
55 MFD 440V Oval Motor Run Capacitor
Our Price:$14.24This oval motor run capacitor is for HVAC service professionals and maintenance teams replacing a capacitor in equipment that requires a 55 MFD, 440V component. It supports motor-run operation in...
-
55/5 MFD 440V Round Run Capacitor
Our Price:$14.24This round run capacitor is for HVAC service professionals maintaining motor-driven equipment that requires 55/5 MFD capacitance at 440V. It provides the specified electrical values needed for...
-
60 Amp Fused Single-Phase Disconnect
Our Price:$51.94This fused single-phase disconnect is for HVAC installers and service professionals working with air conditioning or refrigeration equipment. It provides a readily accessible disconnecting means...
-
60 in. Blue 1/4 in. Refrigerant Hose with Low-Loss Fitting
Our Price:$48.94This 60-inch blue refrigerant hose is for HVAC service professionals connecting manifold and gauge equipment during refrigerant work. Its low-loss fitting helps retain refrigerant in the hose after...
-
60 in. Yellow 1/4 in. Refrigerant Hose with Low-Loss Fitting
Our Price:$48.94This 60-inch yellow 1/4-inch refrigerant hose is for HVAC service professionals working with CFC, HCFC, and HFC refrigerants. It connects service equipment while helping retain refrigerant in the...
-
60-Inch 1/4-Inch Refrigerant Hose Set with Compact Ball Valves
Our Price:$179.94This three-hose refrigerant service set is designed for HVAC technicians who need to connect manifold gauges during refrigerant service. Its compact ball-valve ends help provide controlled access in...
-
60-Inch Refrigeration Hose Set with Ball Valve Adapters
Our Price:$339.94This set of four refrigeration hoses is for HVAC technicians servicing refrigeration systems. Ball valve adapters provide added control of refrigerant loss while connecting and working with...
-
60-Inch Refrigeration Hose Set, 1/4-Inch, Red, Set of 3
Our Price:$94.94This set of three 60-inch refrigeration hoses is for HVAC service professionals working with refrigeration systems. It provides hose connections for servicing systems that use high-pressure...
-
60-Inch Yellow 1/4-Inch Refrigerant Hose with Compact Ball Valve
Our Price:$58.94This 60-inch yellow 1/4-inch refrigerant hose is for HVAC technicians servicing refrigeration and air-conditioning systems. Its compact ball valve end helps control refrigerant flow when connecting...
HVAC Controls, Parts & Service: Everything You Need to Keep Your System Running
Whether you're replacing a worn component, upgrading system controls, or performing routine maintenance, this category covers the essential parts and equipment that keep heating and cooling systems operating efficiently. Use the subcategory paths below to find exactly what your job requires.
Choose your starting point
Popular examples in this category
Keeping HVAC Systems Operational and Efficient
These products support repair, maintenance, and replacement tasks across residential and commercial HVAC systems. From failed capacitors to worn pump bearings, having the right part on hand reduces downtime, restores comfort, and extends the working life of heating and cooling equipment.
Start With the System and the Problem
Identify the system type (hydronic, forced air, refrigeration), the failing or worn component, and the specifications required—voltage, flow rate, pressure rating, or physical dimensions. Matching specs precisely prevents compatibility issues and callbacks on completed jobs.
Where These Parts and Controls Are Used
Common applications include boiler and hydronic heating systems, split and packaged air conditioning units, commercial refrigeration, and ventilation systems. Parts like circulator pumps, capacitors, and aquastats are used in both new installations and service replacement scenarios.
Sourcing Tips and Service Considerations
Always verify OEM specifications or cross-reference part numbers before ordering. For service work, stocking common failure items—capacitors, condensate pumps, and bearings—reduces truck rolls and speeds up repairs. Cleaning equipment supports preventive maintenance programs that lower long-term service costs.
Which Subcategory Do You Need? A Quick Reference
Match your service need to the right subcategory path using this guide.
| Need | Best Fit Subcategory | Why It Matters |
|---|---|---|
| Control boiler water temperature | Aquastats | Aquastats regulate when the boiler fires based on water temperature setpoints, protecting the system and maintaining efficiency |
| Replace a failed motor or pump component | Bearings or Circulator Pump Accessories | Bearings and accessories allow targeted repair without full pump replacement, saving cost and labor time |
| Restore circulation in a hydronic system | Circulator Pumps | The right pump must match system flow rate and head pressure to maintain proper heat distribution |
| Fix a non-starting AC or refrigeration unit | Capacitors or Compressors | Capacitors are a common low-cost fix; if the compressor itself has failed, replacement is required |
| Remove standing water from drain pans | Condensate Pumps | Condensate pumps prevent water damage and mold by actively removing condensate when gravity drainage isn't available |
| Perform seasonal system cleaning | HVAC Cleaning Equipment | Regular coil and drain cleaning maintains airflow, efficiency, and indoor air quality across all system types |
Plan the right fit before choosing
Step 1: Identify the System and Failure Point
Before selecting any part or control, confirm the system type and the specific component that needs attention. Hydronic systems rely heavily on circulator pumps, aquastats, and bearings, while refrigerant-based systems commonly require capacitors and compressors.
- Note the system voltage, BTU capacity, and fluid or refrigerant type
- Check whether the failure is electrical, mechanical, or related to flow and pressure
- Confirm whether you need an exact replacement or an equivalent cross-reference
Step 2: Match Specifications to the Application
Each subcategory has critical spec requirements. Capacitors must match microfarad and voltage ratings. Circulator pumps require correct flow rate and head pressure. Aquastats need the right temperature range for the system they control.
- Use the existing part number or equipment nameplate data as your starting point
- For pumps and compressors, verify flange size, port configuration, and mounting style
- For controls like aquastats, confirm setpoint range and differential settings
Step 3: Plan for Preventive Maintenance
Many service calls can be reduced by stocking high-failure-rate components and scheduling regular cleaning and inspection. HVAC cleaning equipment and condensate pump maintenance are often overlooked until a system failure occurs.
- Stock capacitors and condensate pumps as common wear items for service vans
- Schedule coil and drain line cleaning seasonally to prevent efficiency loss
- Inspect bearings and pump accessories annually in hydronic systems
From aquastats to compressors, each subcategory focuses on a specific part or function so you can navigate directly to what you need.
Most HVAC service calls involve either an electrical component failure (capacitor, control) or a mechanical one (bearing, pump, compressor), and this category covers both.
Parts and controls in this category are used across light residential systems, large commercial HVAC installations, and industrial climate control applications.
Whether you're responding to a breakdown or running a scheduled maintenance program, this category includes parts and equipment for both approaches.
Common questions before buying
How do I know if I need a capacitor or a compressor replacement?
Start with the capacitor—it's a common, low-cost failure point that can prevent a compressor from starting. Test the capacitor first. If it checks out and the compressor still won't run, further diagnosis of the compressor is warranted.
What specifications do I need to replace a circulator pump?
You'll need the flow rate (GPM), head pressure (feet of head), pipe connection size, and voltage. Check the nameplate on the existing pump or the system design documents to confirm these values before ordering.
Can I use HVAC cleaning equipment on both residential and commercial systems?
Yes, but verify that the equipment capacity and chemical compatibility match the system size and coil material. Some commercial systems require higher-pressure coil cleaning tools than those used in residential applications.
What is an aquastat and when does it need to be replaced?
An aquastat is a temperature control device used in hydronic heating systems to regulate boiler operation. It may need replacement if the system short-cycles, fails to reach setpoint, or if the control shows signs of electrical failure during testing.
High-Limit Oil Aquastat Relay, 120VWBB394547
Bluetooth Circulator Pump Communication ModuleWBB1529849
Industrial Plug-In Temperature Controller with Power Cord, 40° to 110°FWBB970415
Clear Plastic Thermostat GuardWBB860061