Cabinets

Electrical cabinets provide enclosed, centralized locations for electrical, electronic and telecommunications components. Common commercial uses include three-phase current transformer service connections, wall-mounted 19-inch rack equipment, and outdoor telephone terminations, helping installers and facility teams organize equipment while planning for access, mounting and available space.

Product Display:
Helpful Buying Guide

Choose an electrical cabinet for the equipment and access your installation requires

The cabinets represented here serve distinct installation needs. Start by identifying whether the cabinet will support current transformer connections, 19-inch rack-mounted electronics, or telephone and telecommunications components. Then compare the stated service range or equipment compatibility, enclosure size, construction, access style and mounting features.

Visual Guide

Popular examples in this category

Use cases

Match the cabinet to the equipment

Current transformer cabinets support three-phase line and load terminations or window-type current transformer wiring. Rack cabinets are intended for 19-inch rack-panel-mounted devices. Telephone cabinets provide a centralized location for telephone terminations and related network components.

How to choose

Confirm fit, capacity and configuration

For CT work, compare the stated amp range, three-phase termination needs, lugs and CT mounting provisions. For electronic equipment, confirm 19-inch rack compatibility and wall-mount needs. Check listed cabinet dimensions when installation space is a key factor.

Applications

Plan around the installation setting

Available options include cabinets stated for indoor or outdoor applications, an outdoor telephone cabinet, wall-mounted rack cabinets for limited floor space, and Type 3R or NEMA 12 cabinet options for the stated enclosure applications.

Additional information

Compare access and construction details

Access choices include hinged covers, double doors and double-hinged front-and-rear access. Some cabinets add a safety-glass viewing window, vents, included mounting screws, lugs, a plywood mounting panel or an integrated wiring buss.

400-1200AStated CT service range

Three-phase service cabinet options cover stated 400 to 1200 amp assemblies.

19 in.Rack compatibility

Wall-mount cabinet options are designed for 19-inch rack-panel-mounted devices.

24 x 24 x 15 in.Listed rack cabinet size

One gray windowed wall-mount cabinet has these listed dimensions.

49.5 x 49.5 x 11.5 in.Telephone cabinet footprint

The outdoor telephone cabinet is listed at this size.

Comparison Guide

Compare cabinet types by intended installation

Use this overview to narrow the category by the equipment being enclosed and the features identified in the product summaries.

Cabinet typeBest suited forFeatures to compare
Current transformer cabinetsThree-phase service connections or window-type CT wiringStated amp range, line and load terminations, lugs, CT mounting hardware, wiring buss, cover or door style
Wall-mount rack cabinets19-inch rack-panel-mounted electronic equipment in limited floor spaceFront and rear access, viewing window, listed dimensions, mounting screws and gasket
Outdoor telephone cabinetTelephone terminations and related network componentsPlywood mounting panel, cabinet footprint and galvanized steel construction
Planning Guide

Plan the right fit before choosing

Current transformer cabinets

Select CT cabinets by electrical configuration and installation features

Current transformer cabinet options are designed for electrical professionals assembling service connections or installing current transformer wiring. The available summaries include cabinets for 400 to 1200 amp three-phase service assemblies, an 800A configuration, and a 400-800A cabinet for window-type current transformers.

  • Look for line and load terminations for each phase and neutral when assembling a three-phase service connection.
  • Compare included lugs, bar-style CT mounting hardware, or an integrated wiring buss based on the stated installation need.
  • Choose from galvanized steel cabinet construction, with select options identified for indoor or outdoor use or Type 3R protection.
  • Consider hinged-cover access or vented double-door configurations where those features suit the application.
Rack equipment cabinets

Prioritize equipment access and visibility for wall-mounted electronics

Wall-mount cabinets in this category are designed for 19-inch rack-panel-mounted devices and other electronic equipment where floor space is limited. Double-hinged designs provide access from the front and rear, while safety-glass windows allow users to check enclosed equipment without opening the cabinet.

  • Confirm the cabinet is designed for 19-inch rack equipment.
  • Use double-hinged access when front and rear access to installed equipment is needed.
  • Compare listed dimensions, including a 24 x 24 x 15 inch option, against the available wall space.
  • Included hardware on select models consists of twenty 10-32 screws; one option also includes a foam-in-place gasket.
Telephone and telecommunications cabinets

Plan mounting space for outdoor telephone components

The outdoor telephone cabinet is intended for telephone terminations and related network components. Its plywood panel provides a mounting surface for compatible components, while its listed cabinet footprint helps buyers assess space for multiple assemblies.

  • Use the 3/4-inch-thick plywood panel for mounting compatible telephone and telecommunications components.
  • Review the 49.5 x 49.5 x 11.5 inch cabinet footprint for installation planning.
  • The cabinet is described with 16- or 14-gauge galvanized steel construction for outdoor enclosure applications.
FAQ

Common questions before buying

What are current transformer cabinets used for?

They provide an enclosed location for current transformer connections or wiring, including options for three-phase service line and load terminations and window-type current transformer applications.

Are there cabinets for 19-inch rack equipment?

Yes. Wall-mount cabinet options are designed for 19-inch rack-panel-mounted devices and provide double-hinged front and rear access.

Can equipment be viewed without opening certain rack cabinets?

Yes. Select wall-mount rack cabinets include a safety-glass viewing window for checking enclosed equipment without opening the cabinet.

What mounting surface does the outdoor telephone cabinet include?

It includes a 3/4-inch-thick plywood mounting panel for compatible telephone and telecommunications components.