-
2-Way Smart HVAC Manifold with Clamps
Our Price:$485.94This 2-way smart manifold is for HVAC service technicians diagnosing and servicing A/C systems. It combines system readings, vacuum measurement, and calculated values in one handheld service tool to...
-
20 MFD 440V Oval Motor Run Capacitor
Our Price:$10.49This oval motor run capacitor is for HVAC service professionals and maintenance teams replacing a capacitor in compatible motor systems. It provides 20 MFD capacitance at 440V to support motor...
-
20/5 MFD 440V Round Run Capacitor
Our Price:$10.24This round motor-run capacitor is for HVAC service professionals and maintenance teams replacing a compatible run capacitor in motor-driven equipment. It provides 20/5 MFD capacitance at 440V to...
-
230V Condensate Removal Pump
Our Price:$99.94This 230V condensate removal pump is for HVAC professionals and facility teams who need to move condensate from air-conditioning or high-efficiency gas furnace systems when gravity drainage is...
-
24 ft Lift 115V Condensate Pump
Our Price:$109.94This 115V condensate pump is designed for air-conditioning and boiler condensate applications. It helps maintenance teams move collected condensate where a 24-foot lift is needed.The pump has a...
-
24 in. Dual-Fan Mini-Split Condenser Stand
Our Price:$465.94This elevated stand is designed for HVAC professionals mounting dual-fan mini-split condensers. It raises the condenser off the ground while providing a stable support platform for installation.The...
-
24V Electric Heat Fan Sequencer with 5-Second Stage Delay
Our Price:$31.94This 24V sequencer is for HVAC professionals servicing electric heating systems. It coordinates fan and heat sequencing functions, helping control the order in which connected stages operate.The...
-
24V Fan and Heat Sequencer for Multi-Stage Electric Heat
Our Price:$16.99This 24V fan and heat sequencer is for HVAC professionals servicing electric heating systems with multi-stage fan and heat sequencing. It coordinates the order of operating stages to support...
-
24V Fan and Heat Sequencer with 5-Second Stage Delay
Our Price:$21.99This 24V sequencer helps HVAC service professionals coordinate fan and heat sequencing in electric heating systems. It manages staged operation so contacts activate in sequence for controlled system...
-
25 + 5 MFD 440V Round Run Capacitor
Our Price:$11.24This round run capacitor is for HVAC technicians and service professionals maintaining motor-driven equipment. It provides 25 + 5 MFD capacitance at 440V to support compatible run-capacitor...
-
25 ft Flexible Tube Cleaning Shaft for 9/16 in. to 1 in. ID Tubes
Our Price:$429.94This flexible tube cleaning shaft is used by HVAC service professionals for wet cleaning of tubes with inside diameters from 9/16 in. to 1 in. It provides the reach and flexibility needed to drive a...
-
25 ft Flexible Tube Cleaning Shaft with Quick-Connect Brush Fitting
Our Price:$459.94This flexible tube cleaning shaft is for HVAC service teams performing wet tube cleaning. It connects to a compatible quick-connect brush to help clean tubes with inside diameters from 9/16 to 1 inch...
-
25 ft Nylon-Cased Flexible Tube Cleaning Shaft for 7/16 in. to 1/2 in. ID Tubes
Our Price:$429.94This flexible tube cleaning shaft is for HVAC maintenance professionals performing wet cleaning of tubes with 7/16 in. to 1/2 in. inside diameters. It provides the reach and flexibility needed to...
-
25 ft. Flexible Tube Cleaning Shaft with Nylon Casing for Quick-Connect Brushes
Our Price:$435.94This flexible tube cleaning shaft is for HVAC service professionals cleaning wet tubes with compatible tube-cleaning equipment. It connects to quick-connect brushes to help reach through 25-foot tube...
-
25 MFD 440V Oval Run Capacitor
Our Price:$10.99This 25 MFD, 440V oval run capacitor is for HVAC service professionals working with motor-run capacitor applications. It provides the specified electrical capacity and voltage rating needed for...
-
25 PSI Open / 50 PSI Closed Pressure Switch
Our Price:$20.99This pressure switch is for HVAC professionals servicing low-pressure control and condenser fan cycling applications. It monitors system pressure to open at 25 PSI and close at 50 PSI, helping...
-
25/5 MFD 370V Oval Run Capacitor
Our Price:$7.59This oval run capacitor is for HVAC technicians and maintenance professionals servicing compatible equipment. It provides 25/5 MFD capacitance at 370V to support run-capacitor replacement work.The...
-
3 Amp Fuse Tester with Light
Our Price:$22.49This 3 amp fuse tester is for HVAC technicians servicing low-voltage circuits on furnaces, boilers, air handlers, and other systems with fused circuit boards. It plugs into the circuit board to help...
-
3-1/8-Inch Protective Gauge Boot Set
Our Price:$28.94This protective gauge boot set is for HVAC service professionals who use 3-1/8-inch gauges. It slips around a gauge to provide cushioning and protection during service work.The rubber boots fit...
-
3-Speed 220V Circulator Water Pump
Our Price:$345.94This 220V circulator water pump is designed for residential hot-water and heating-system users who need to move water through compatible loop systems. Its three-speed operation helps users select the...
HVAC Controls, Parts & Service: Everything You Need to Keep Your System Running
Whether you're replacing a worn component, upgrading system controls, or performing routine maintenance, this category covers the essential parts and equipment that keep heating and cooling systems operating efficiently. Use the subcategory paths below to find exactly what your job requires.
Choose your starting point
Popular examples in this category
Keeping HVAC Systems Operational and Efficient
These products support repair, maintenance, and replacement tasks across residential and commercial HVAC systems. From failed capacitors to worn pump bearings, having the right part on hand reduces downtime, restores comfort, and extends the working life of heating and cooling equipment.
Start With the System and the Problem
Identify the system type (hydronic, forced air, refrigeration), the failing or worn component, and the specifications required—voltage, flow rate, pressure rating, or physical dimensions. Matching specs precisely prevents compatibility issues and callbacks on completed jobs.
Where These Parts and Controls Are Used
Common applications include boiler and hydronic heating systems, split and packaged air conditioning units, commercial refrigeration, and ventilation systems. Parts like circulator pumps, capacitors, and aquastats are used in both new installations and service replacement scenarios.
Sourcing Tips and Service Considerations
Always verify OEM specifications or cross-reference part numbers before ordering. For service work, stocking common failure items—capacitors, condensate pumps, and bearings—reduces truck rolls and speeds up repairs. Cleaning equipment supports preventive maintenance programs that lower long-term service costs.
Which Subcategory Do You Need? A Quick Reference
Match your service need to the right subcategory path using this guide.
| Need | Best Fit Subcategory | Why It Matters |
|---|---|---|
| Control boiler water temperature | Aquastats | Aquastats regulate when the boiler fires based on water temperature setpoints, protecting the system and maintaining efficiency |
| Replace a failed motor or pump component | Bearings or Circulator Pump Accessories | Bearings and accessories allow targeted repair without full pump replacement, saving cost and labor time |
| Restore circulation in a hydronic system | Circulator Pumps | The right pump must match system flow rate and head pressure to maintain proper heat distribution |
| Fix a non-starting AC or refrigeration unit | Capacitors or Compressors | Capacitors are a common low-cost fix; if the compressor itself has failed, replacement is required |
| Remove standing water from drain pans | Condensate Pumps | Condensate pumps prevent water damage and mold by actively removing condensate when gravity drainage isn't available |
| Perform seasonal system cleaning | HVAC Cleaning Equipment | Regular coil and drain cleaning maintains airflow, efficiency, and indoor air quality across all system types |
Plan the right fit before choosing
Step 1: Identify the System and Failure Point
Before selecting any part or control, confirm the system type and the specific component that needs attention. Hydronic systems rely heavily on circulator pumps, aquastats, and bearings, while refrigerant-based systems commonly require capacitors and compressors.
- Note the system voltage, BTU capacity, and fluid or refrigerant type
- Check whether the failure is electrical, mechanical, or related to flow and pressure
- Confirm whether you need an exact replacement or an equivalent cross-reference
Step 2: Match Specifications to the Application
Each subcategory has critical spec requirements. Capacitors must match microfarad and voltage ratings. Circulator pumps require correct flow rate and head pressure. Aquastats need the right temperature range for the system they control.
- Use the existing part number or equipment nameplate data as your starting point
- For pumps and compressors, verify flange size, port configuration, and mounting style
- For controls like aquastats, confirm setpoint range and differential settings
Step 3: Plan for Preventive Maintenance
Many service calls can be reduced by stocking high-failure-rate components and scheduling regular cleaning and inspection. HVAC cleaning equipment and condensate pump maintenance are often overlooked until a system failure occurs.
- Stock capacitors and condensate pumps as common wear items for service vans
- Schedule coil and drain line cleaning seasonally to prevent efficiency loss
- Inspect bearings and pump accessories annually in hydronic systems
From aquastats to compressors, each subcategory focuses on a specific part or function so you can navigate directly to what you need.
Most HVAC service calls involve either an electrical component failure (capacitor, control) or a mechanical one (bearing, pump, compressor), and this category covers both.
Parts and controls in this category are used across light residential systems, large commercial HVAC installations, and industrial climate control applications.
Whether you're responding to a breakdown or running a scheduled maintenance program, this category includes parts and equipment for both approaches.
Common questions before buying
How do I know if I need a capacitor or a compressor replacement?
Start with the capacitor—it's a common, low-cost failure point that can prevent a compressor from starting. Test the capacitor first. If it checks out and the compressor still won't run, further diagnosis of the compressor is warranted.
What specifications do I need to replace a circulator pump?
You'll need the flow rate (GPM), head pressure (feet of head), pipe connection size, and voltage. Check the nameplate on the existing pump or the system design documents to confirm these values before ordering.
Can I use HVAC cleaning equipment on both residential and commercial systems?
Yes, but verify that the equipment capacity and chemical compatibility match the system size and coil material. Some commercial systems require higher-pressure coil cleaning tools than those used in residential applications.
What is an aquastat and when does it need to be replaced?
An aquastat is a temperature control device used in hydronic heating systems to regulate boiler operation. It may need replacement if the system short-cycles, fails to reach setpoint, or if the control shows signs of electrical failure during testing.
High-Limit Oil Aquastat Relay, 120VWBB394547
Bluetooth Circulator Pump Communication ModuleWBB1529849
Industrial Plug-In Temperature Controller with Power Cord, 40° to 110°FWBB970415
Clear Plastic Thermostat GuardWBB860061