-
Adjustable Open-on-Rise Thermostat, 135 to 175°F
Our Price:$15.99This adjustable thermostat is used by maintenance teams and service professionals in heater and dryer applications to control temperature response. It opens when the temperature rises within its...
-
Adjustable Open-on-Rise Thermostat, 175 to 215°F
Our Price:$17.74This adjustable thermostat limit switch is for maintenance teams servicing heater and dryer applications. It opens as temperature rises within its adjustable range to support temperature control in...
-
Aluminum Spray Wand for CoilJet Gun
Our Price:$119.94This aluminum spray wand is an HVAC cleaning accessory for technicians servicing condensers, evaporators, and refrigeration units. It helps direct spray into confined areas that can be difficult to...
-
Aquastat Immersion Well, 1/2 in. Pipe Connection
Our Price:$33.94This immersion well is an aquastat accessory for HVAC technicians and maintenance professionals. It provides a mounting point for compatible aquastat controls in systems using a 1/2 in. pipe...
-
Aquastat Immersion Well, 3/4 in. Pipe Connection, 3/8 in. Insertion Diameter, 1-1/2 in. Deep
Our Price:$35.94This immersion well is an aquastat accessory for HVAC technicians and maintenance professionals who need to position an aquastat sensing element in a pipe connection. It provides a defined 1-1/2...
-
Aquastat Relay with High Limit and Adjustable Differential
Our Price:$455.94This aquastat relay is a temperature control for HVAC professionals who need to manage high-limit protection, low-limit operation, and circulation control in compatible heating systems.The relay...
-
Automatic 115V Condensate Removal Pump, 65 GPH
Our Price:$94.94This automatic condensate removal pump is designed for HVAC professionals and facility maintenance teams that need to collect and discharge condensate from air conditioning equipment, dehumidifiers,...
-
Auxiliary Condensate Overflow Safety Switch with 18-Inch Wire
Our Price:$30.94This auxiliary condensate overflow safety switch is for HVAC and refrigeration technicians who need to monitor condensate drain pans. It helps protect air-conditioning or refrigeration equipment by...
-
Auxiliary Condensate Overflow Safety Switch with 72-Inch Wire
Our Price:$29.94This auxiliary condensate overflow safety switch is for HVAC and refrigeration professionals who need to monitor condensate drain pans. It helps protect equipment by shutting down the unit or...
-
Auxiliary Condensate Overflow Safety Switch, 5A
Our Price:$17.74This auxiliary condensate overflow safety switch is for facilities and service professionals maintaining air-conditioning or refrigeration units. Installed in the condensate drain pan, it helps...
-
Blue Compound Refrigerant Gauge for R-134A, R-404A and R-407C
Our Price:$52.94This blue compound refrigerant gauge is designed for HVAC service professionals who need to monitor compound pressure and temperature scales for R-134A, R-404A, and R-407C refrigerants. It provides a...
-
Blue Compound Refrigerant Gauge for R-22, R-404A and R-410A
Our Price:$44.94This blue compound gauge is for HVAC service professionals who need to monitor compound pressure and temperature scales when working with R-22, R-404A, or R-410A refrigerants. Its color-coded face...
-
Blue Compound °F Gauge with 1/8 in. NPT Male Connection
Our Price:$33.94This blue compound °F gauge is for HVAC service professionals who need to monitor compound pressure readings during system service. Its surge-protected design helps reduce needle movement for clearer...
-
Blue Manifold Handle with Screw
Our Price:$10.24This blue handle with screw is a manifold component for HVAC service professionals. It is used with a compatible manifold to provide a handle component for servicing and maintaining the manifold...
-
Blue Nylon Quick-Connect Tube Cleaning Brushes for 3/4 in. ID Tubes, Pack of 25
Our Price:$129.94These blue nylon tube-cleaning brushes are for HVAC service professionals cleaning soft deposits from straight tubes. They help remove mud and algae from ferrous and nonferrous tubing with a 3/4 in...
-
Blue Nylon Tube Cleaning Brush for 5/16-Inch ID Tubes, Pack of 15
Our Price:$82.94These blue nylon tube cleaning brushes are for HVAC service teams cleaning straight ferrous and nonferrous tubes with a 5/16-inch inside diameter. They help remove soft buildup, including mud and...
-
Blue Nylon Tube Cleaning Brush with Quick Connect for 1/2 in. ID Tubes, 25-Pack
Our Price:$139.94This blue nylon tube-cleaning brush is for maintenance teams cleaning soft deposits from straight ferrous and nonferrous tubes. It is designed to help remove mud and algae from 1/2 in...
-
Blue Nylon Tube Cleaning Brushes for 1/4 in. ID Tubes, Pack of 15
Our Price:$82.94These blue nylon tube cleaning brushes are for HVAC service professionals cleaning straight ferrous and nonferrous tubes with a 1/4 in. inside diameter. They help remove soft buildup, including mud...
-
Blue Nylon Tube Cleaning Brushes for 3/8-Inch ID Tubes, Pack of 15
Our Price:$82.94These blue nylon tube cleaning brushes are for HVAC service professionals cleaning straight ferrous and nonferrous tubes with a 3/8-inch inside diameter. They help remove soft buildup, including mud...
-
Blue Nylon Tube Cleaning Brushes with Quick Connect, 5/8 in. ID, 25-Pack
Our Price:$139.94These blue nylon tube-cleaning brushes are for HVAC service professionals cleaning straight ferrous and nonferrous tubes. They help remove soft deposits, including mud and algae, from 5/8 in...
HVAC Controls, Parts & Service: Everything You Need to Keep Your System Running
Whether you're replacing a worn component, upgrading system controls, or performing routine maintenance, this category covers the essential parts and equipment that keep heating and cooling systems operating efficiently. Use the subcategory paths below to find exactly what your job requires.
Choose your starting point
Popular examples in this category
Keeping HVAC Systems Operational and Efficient
These products support repair, maintenance, and replacement tasks across residential and commercial HVAC systems. From failed capacitors to worn pump bearings, having the right part on hand reduces downtime, restores comfort, and extends the working life of heating and cooling equipment.
Start With the System and the Problem
Identify the system type (hydronic, forced air, refrigeration), the failing or worn component, and the specifications required—voltage, flow rate, pressure rating, or physical dimensions. Matching specs precisely prevents compatibility issues and callbacks on completed jobs.
Where These Parts and Controls Are Used
Common applications include boiler and hydronic heating systems, split and packaged air conditioning units, commercial refrigeration, and ventilation systems. Parts like circulator pumps, capacitors, and aquastats are used in both new installations and service replacement scenarios.
Sourcing Tips and Service Considerations
Always verify OEM specifications or cross-reference part numbers before ordering. For service work, stocking common failure items—capacitors, condensate pumps, and bearings—reduces truck rolls and speeds up repairs. Cleaning equipment supports preventive maintenance programs that lower long-term service costs.
Which Subcategory Do You Need? A Quick Reference
Match your service need to the right subcategory path using this guide.
| Need | Best Fit Subcategory | Why It Matters |
|---|---|---|
| Control boiler water temperature | Aquastats | Aquastats regulate when the boiler fires based on water temperature setpoints, protecting the system and maintaining efficiency |
| Replace a failed motor or pump component | Bearings or Circulator Pump Accessories | Bearings and accessories allow targeted repair without full pump replacement, saving cost and labor time |
| Restore circulation in a hydronic system | Circulator Pumps | The right pump must match system flow rate and head pressure to maintain proper heat distribution |
| Fix a non-starting AC or refrigeration unit | Capacitors or Compressors | Capacitors are a common low-cost fix; if the compressor itself has failed, replacement is required |
| Remove standing water from drain pans | Condensate Pumps | Condensate pumps prevent water damage and mold by actively removing condensate when gravity drainage isn't available |
| Perform seasonal system cleaning | HVAC Cleaning Equipment | Regular coil and drain cleaning maintains airflow, efficiency, and indoor air quality across all system types |
Plan the right fit before choosing
Step 1: Identify the System and Failure Point
Before selecting any part or control, confirm the system type and the specific component that needs attention. Hydronic systems rely heavily on circulator pumps, aquastats, and bearings, while refrigerant-based systems commonly require capacitors and compressors.
- Note the system voltage, BTU capacity, and fluid or refrigerant type
- Check whether the failure is electrical, mechanical, or related to flow and pressure
- Confirm whether you need an exact replacement or an equivalent cross-reference
Step 2: Match Specifications to the Application
Each subcategory has critical spec requirements. Capacitors must match microfarad and voltage ratings. Circulator pumps require correct flow rate and head pressure. Aquastats need the right temperature range for the system they control.
- Use the existing part number or equipment nameplate data as your starting point
- For pumps and compressors, verify flange size, port configuration, and mounting style
- For controls like aquastats, confirm setpoint range and differential settings
Step 3: Plan for Preventive Maintenance
Many service calls can be reduced by stocking high-failure-rate components and scheduling regular cleaning and inspection. HVAC cleaning equipment and condensate pump maintenance are often overlooked until a system failure occurs.
- Stock capacitors and condensate pumps as common wear items for service vans
- Schedule coil and drain line cleaning seasonally to prevent efficiency loss
- Inspect bearings and pump accessories annually in hydronic systems
From aquastats to compressors, each subcategory focuses on a specific part or function so you can navigate directly to what you need.
Most HVAC service calls involve either an electrical component failure (capacitor, control) or a mechanical one (bearing, pump, compressor), and this category covers both.
Parts and controls in this category are used across light residential systems, large commercial HVAC installations, and industrial climate control applications.
Whether you're responding to a breakdown or running a scheduled maintenance program, this category includes parts and equipment for both approaches.
Common questions before buying
How do I know if I need a capacitor or a compressor replacement?
Start with the capacitor—it's a common, low-cost failure point that can prevent a compressor from starting. Test the capacitor first. If it checks out and the compressor still won't run, further diagnosis of the compressor is warranted.
What specifications do I need to replace a circulator pump?
You'll need the flow rate (GPM), head pressure (feet of head), pipe connection size, and voltage. Check the nameplate on the existing pump or the system design documents to confirm these values before ordering.
Can I use HVAC cleaning equipment on both residential and commercial systems?
Yes, but verify that the equipment capacity and chemical compatibility match the system size and coil material. Some commercial systems require higher-pressure coil cleaning tools than those used in residential applications.
What is an aquastat and when does it need to be replaced?
An aquastat is a temperature control device used in hydronic heating systems to regulate boiler operation. It may need replacement if the system short-cycles, fails to reach setpoint, or if the control shows signs of electrical failure during testing.
High-Limit Oil Aquastat Relay, 120VWBB394547
Bluetooth Circulator Pump Communication ModuleWBB1529849
Industrial Plug-In Temperature Controller with Power Cord, 40° to 110°FWBB970415
Clear Plastic Thermostat GuardWBB860061