-
Three-Pack 1/4-Inch Charging Hoses with Valve
Our Price:$209.94This three-pack of 1/4-inch charging hoses is designed for HVAC service professionals who need hose connections for charging work. A valve at the hose end helps users manage flow while working around...
-
Three-Speed 115V Cast Iron Circulator Water Pump
Our Price:$249.94This three-speed circulator water pump is designed for HVAC professionals and maintenance teams who need to circulate water in compatible systems. Its selectable speeds help users match pump...
-
Three-Terminal Compressor Repair Lugs
Our Price:$49.94These three-terminal repair lugs help HVAC service professionals restore compressor connections with damaged or corroded spade terminals. They provide a replacement connection for standard compressor...
-
Three-Wing Belt Drive Bearing Bracket for 15-Inch Blowers
Our Price:$109.94This three-wing belt drive bearing bracket is a blower component for HVAC service professionals and maintenance teams working with 15-inch blowers. It supports belt drive bearing mounting within...
-
Three-Wing Belt Drive Bearing Bracket with 1 in. Shaft
Our Price:$259.94This three-wing belt drive bearing bracket is a motor mounting part for HVAC professionals servicing 9 to 16 in. blowers. It provides a bracket, bearings, and shaft assembly for belt-drive blower...
-
Three-Wing Belt Drive Bracket
Our Price:$52.94This three-wing belt drive bracket is a motor mounting part for HVAC professionals working with 9 to 16 inch blowers. It provides a mounting solution for belt-drive blower assemblies.The bracket has...
-
Tri-Tube Bender for 1/4 in., 5/16 in. and 3/8 in. Tubing
Our Price:$58.94This tri-tube bender is an HVAC installation and maintenance tool for technicians who need to form tubing accurately. It helps users identify tube size, align the tube for bending, and create bends...
-
Triple Aquastat Relay with Fixed Low Limit
Our Price:$475.94This triple aquastat relay is an HVAC control component for technicians and facilities teams servicing aquastat-equipped systems. It provides high-limit control along with a fixed low-limit setting...
-
Triple Aquastat Relay with High Limit - 4.8 W x 4.5 H x 6.4 D
Our Price:$455.94This triple aquastat relay is an HVAC control component for technicians and maintenance professionals who need to manage temperature-related system operation. Its high-limit function and adjustable...
-
Triple Aquastat Relay with High Limit for Gas Systems
Our Price:$495.94This triple aquastat relay is for HVAC professionals and service teams working on gas systems. It combines relay operation with a high-limit function to support temperature-control service and...
-
Tube Piercing Pliers for Copper Tubing
Our Price:$67.94These tube piercing pliers are an HVAC service tool for technicians working with copper tubing during refrigerant recovery. They clamp onto the tube and pierce it to create an access point for the...
-
Two-Way Brass Manifold Gauge Set with Hoses and Fittings
Our Price:$75.94This two-way manifold gauge set is for HVAC service professionals who need to work with A/C system gauges, hoses, and fittings. It supports system service tasks by providing a manifold assembly with...
-
Universal 410A Valve Core Remover Kit
Our Price:$70.94This universal valve core remover kit is for HVAC technicians who need to access valve cores during refrigerant service work. Its safety nut and locking mechanism are designed to support valve-core...
-
Universal AC Disposable Dye Injectors, 2-Pack
Our Price:$67.94These universal AC disposable dye injectors help HVAC service technicians dispense dye into air-conditioning systems for leak-detection work. Each injector provides a practical way to introduce dye...
-
Universal Multi-Value HVAC Capacitor, 2.5–67.5 MFD, 370/440V
Our Price:$99.94This multi-value HVAC capacitor is for service professionals maintaining motor-run and motor-start applications. It provides a practical replacement option that can cover multiple capacitance values,...
-
Universal Steel Thermostat Guard with Mounting Ring Base
Our Price:$47.94This universal thermostat guard helps facility managers and maintenance teams limit unauthorized temperature changes at room thermostats. It covers the thermostat to support controlled HVAC settings...
-
Universal Thermostat Guard with Clear Cover and Mounting Plate
Our Price:$32.94This universal thermostat guard is for facility teams and maintenance staff who need to cover compatible room thermostats while keeping the control visible. It provides an enclosed cover arrangement...
-
Universal-Fit Self-Tapping Saddle Valve
Our Price:$14.99This self-tapping saddle valve is a combination clamp and valve assembly for buyers installing water connections for ice makers and humidifiers. Its universal-fit design provides a practical...
-
Valve Core Remover and Installer with HVAC Access Port
Our Price:$61.94This valve core remover and installer with an HVAC access port is for HVAC service professionals performing refrigerant recovery, evacuation, and recharge work. It temporarily removes a service valve...
-
Washable Hog Hair Air Filter, 30 in. x 20 in. x 1 in.
Our Price:$13.49This washable hog hair air filter is for facilities and maintenance teams servicing forced-air systems. It provides reusable filter media for routine air-system upkeep.The natural-fiber filter...
HVAC Controls, Parts & Service: Everything You Need to Keep Your System Running
Whether you're replacing a worn component, upgrading system controls, or performing routine maintenance, this category covers the essential parts and equipment that keep heating and cooling systems operating efficiently. Use the subcategory paths below to find exactly what your job requires.
Choose your starting point
Popular examples in this category
Keeping HVAC Systems Operational and Efficient
These products support repair, maintenance, and replacement tasks across residential and commercial HVAC systems. From failed capacitors to worn pump bearings, having the right part on hand reduces downtime, restores comfort, and extends the working life of heating and cooling equipment.
Start With the System and the Problem
Identify the system type (hydronic, forced air, refrigeration), the failing or worn component, and the specifications required—voltage, flow rate, pressure rating, or physical dimensions. Matching specs precisely prevents compatibility issues and callbacks on completed jobs.
Where These Parts and Controls Are Used
Common applications include boiler and hydronic heating systems, split and packaged air conditioning units, commercial refrigeration, and ventilation systems. Parts like circulator pumps, capacitors, and aquastats are used in both new installations and service replacement scenarios.
Sourcing Tips and Service Considerations
Always verify OEM specifications or cross-reference part numbers before ordering. For service work, stocking common failure items—capacitors, condensate pumps, and bearings—reduces truck rolls and speeds up repairs. Cleaning equipment supports preventive maintenance programs that lower long-term service costs.
Which Subcategory Do You Need? A Quick Reference
Match your service need to the right subcategory path using this guide.
| Need | Best Fit Subcategory | Why It Matters |
|---|---|---|
| Control boiler water temperature | Aquastats | Aquastats regulate when the boiler fires based on water temperature setpoints, protecting the system and maintaining efficiency |
| Replace a failed motor or pump component | Bearings or Circulator Pump Accessories | Bearings and accessories allow targeted repair without full pump replacement, saving cost and labor time |
| Restore circulation in a hydronic system | Circulator Pumps | The right pump must match system flow rate and head pressure to maintain proper heat distribution |
| Fix a non-starting AC or refrigeration unit | Capacitors or Compressors | Capacitors are a common low-cost fix; if the compressor itself has failed, replacement is required |
| Remove standing water from drain pans | Condensate Pumps | Condensate pumps prevent water damage and mold by actively removing condensate when gravity drainage isn't available |
| Perform seasonal system cleaning | HVAC Cleaning Equipment | Regular coil and drain cleaning maintains airflow, efficiency, and indoor air quality across all system types |
Plan the right fit before choosing
Step 1: Identify the System and Failure Point
Before selecting any part or control, confirm the system type and the specific component that needs attention. Hydronic systems rely heavily on circulator pumps, aquastats, and bearings, while refrigerant-based systems commonly require capacitors and compressors.
- Note the system voltage, BTU capacity, and fluid or refrigerant type
- Check whether the failure is electrical, mechanical, or related to flow and pressure
- Confirm whether you need an exact replacement or an equivalent cross-reference
Step 2: Match Specifications to the Application
Each subcategory has critical spec requirements. Capacitors must match microfarad and voltage ratings. Circulator pumps require correct flow rate and head pressure. Aquastats need the right temperature range for the system they control.
- Use the existing part number or equipment nameplate data as your starting point
- For pumps and compressors, verify flange size, port configuration, and mounting style
- For controls like aquastats, confirm setpoint range and differential settings
Step 3: Plan for Preventive Maintenance
Many service calls can be reduced by stocking high-failure-rate components and scheduling regular cleaning and inspection. HVAC cleaning equipment and condensate pump maintenance are often overlooked until a system failure occurs.
- Stock capacitors and condensate pumps as common wear items for service vans
- Schedule coil and drain line cleaning seasonally to prevent efficiency loss
- Inspect bearings and pump accessories annually in hydronic systems
From aquastats to compressors, each subcategory focuses on a specific part or function so you can navigate directly to what you need.
Most HVAC service calls involve either an electrical component failure (capacitor, control) or a mechanical one (bearing, pump, compressor), and this category covers both.
Parts and controls in this category are used across light residential systems, large commercial HVAC installations, and industrial climate control applications.
Whether you're responding to a breakdown or running a scheduled maintenance program, this category includes parts and equipment for both approaches.
Common questions before buying
How do I know if I need a capacitor or a compressor replacement?
Start with the capacitor—it's a common, low-cost failure point that can prevent a compressor from starting. Test the capacitor first. If it checks out and the compressor still won't run, further diagnosis of the compressor is warranted.
What specifications do I need to replace a circulator pump?
You'll need the flow rate (GPM), head pressure (feet of head), pipe connection size, and voltage. Check the nameplate on the existing pump or the system design documents to confirm these values before ordering.
Can I use HVAC cleaning equipment on both residential and commercial systems?
Yes, but verify that the equipment capacity and chemical compatibility match the system size and coil material. Some commercial systems require higher-pressure coil cleaning tools than those used in residential applications.
What is an aquastat and when does it need to be replaced?
An aquastat is a temperature control device used in hydronic heating systems to regulate boiler operation. It may need replacement if the system short-cycles, fails to reach setpoint, or if the control shows signs of electrical failure during testing.
High-Limit Oil Aquastat Relay, 120VWBB394547
Bluetooth Circulator Pump Communication ModuleWBB1529849
Industrial Plug-In Temperature Controller with Power Cord, 40° to 110°FWBB970415
Clear Plastic Thermostat GuardWBB860061