Copper Tubing Pinch-Off Plier
Our Price:$17.49This pinch-off plier is a refrigeration service tool for technicians who need to pinch and lock copper tubing during refrigeration work. It provides a dedicated way to close off tubing as part of...
-
Deluxe Oil Line Blow-Out Gun Kit with Gauge and Carrying Case
Our Price:$129.94This deluxe blow-out gun kit is an HVAC maintenance tool for service technicians working with oil lines. Its gauge helps users monitor whether an oil line plug is moving back toward the tank,...
-
Direct-Drive Motor Mounting Bracket for 12-Inch Blowers
Our Price:$99.94This direct-drive motor mounting bracket is for users mounting a 12-inch blower. It provides a dedicated bracket for positioning the motor during blower installation.Designed for direct-drive...
-
Direct-Drive Motor Mounting Bracket for 9-Inch Blowers
Our Price:$62.94This direct-drive motor mounting bracket helps HVAC professionals mount a 9-inch blower. It provides a dedicated support component for blower installation and motor mounting applications.The bracket...
-
Drive-End Repair Coupling for SC-TC-S02 and GTC-702 Flexible Shafts
Our Price:$14.49This drive-end repair coupling is a replacement part for technicians servicing compatible HVAC cleaning equipment. It is used to repair the drive end of SC-TC-S02 and GTC-702 flexible shafts.The...
-
Drive-End Repair Coupling for SC-TC-S03 and GTC-703 Flexible Shafts
Our Price:$14.49This drive-end repair coupling is a replacement part for HVAC cleaning equipment users who need to repair compatible flexible shafts. It supports restoration of the drive-end connection on SC-TC-S03...
-
Dryer Booster Fan Pressure Sensing Switch
Our Price:$139.94This pressure sensing switch is for operators of dryer booster fan systems. It detects positive pressure in the duct line to automatically start the booster fan when needed.The switch supports...
-
Dual High-Limit Circulator Aquastat Controller with 10°F Differential
Our Price:$365.94This dual aquastat controller is for HVAC service professionals who need to manage high-limit and circulator temperature control. It provides a practical control point for equipment requiring...
-
Dual High-Low Limit Aquastat Controller
Our Price:$375.94This dual high-low limit aquastat controller is for HVAC professionals who need to set separate upper and lower temperature limits. It provides high-limit and low-limit control settings in one...
-
Dual Run Capacitor, 70 + 5 MFD, 440V, Round
Our Price:$16.74This round dual run capacitor is for HVAC service professionals maintaining motor-driven equipment. Its 70 + 5 MFD rating provides the electrical capacitance needed to support motor operation in...
-
Dual-Diameter Nylon Tube Cleaning Brush for 15/16 in. ID Tubes, 25-Pack
Our Price:$235.94This dual-diameter nylon brush is designed for HVAC service professionals cleaning straight, internally enhanced tubes with a 15/16 in. inside diameter. It helps remove soft deposits, including mud...
-
Dual-Diameter Nylon Tube Cleaning Brush, 5/8 in. ID, Quick Connect, Pack of 25
Our Price:$235.94This dual-diameter nylon brush is used by HVAC service professionals to remove soft deposits, such as mud and algae, from straight internally enhanced tubes. Its two-ended design helps clean the...
-
Dual-Diameter Nylon Tube Cleaning Brush, Quick Connect, 15/16 in. ID, Pack of 25
Our Price:$235.94This dual-diameter nylon brush is for maintenance professionals cleaning soft deposits from straight, internally enhanced ferrous and nonferrous tubes. It helps remove mud, algae, and similar buildup...
-
Dual-Diameter Nylon Tube Cleaning Brushes for 5/8 in. ID Tubes, 25-Pack
Our Price:$235.94These dual-diameter nylon brushes help maintenance teams clean soft deposits from straight, internally enhanced tubes with a 5/8 in. inside diameter. Their two-ended design is made to reach both the...
-
Economy High-Side R-134a Service Coupler
Our Price:$58.94This economy high-side service coupler is for HVAC service professionals working with R-134a systems. It provides a straightforward connection for service access and allows flow as soon as it is...
-
Economy Low-Side R-134A Service Coupler
Our Price:$57.94This economy low-side service coupler is for HVAC service personnel working with R-134A systems. It snaps onto the connection to provide immediate flow during service.The coupler is designed for...
-
Enhanced Dual-Diameter Spin-Grit Tube Cleaning Brush, Pack of 15
Our Price:$135.94This 15-pack of dual-diameter Spin-Grit brushes is for HVAC service professionals cleaning straight, internally enhanced ferrous and nonferrous tubes. It helps remove soft, light scale deposits from...
-
Enhanced Spin-Grit Brush with Quick Connect for 1/2-Inch ID Tubes, Pack of 15
Our Price:$135.94This pack of enhanced spin-grit brushes is designed for HVAC service professionals cleaning internally enhanced or spiraled 1/2-inch ID tubes. It helps remove soft, light scale deposits from straight...
-
Enhanced Spin-Grit Tube Cleaning Brush, 1 to 1-1/4 in. ID, 15-Pack
Our Price:$135.94This 15-pack of enhanced spin-grit brushes is for HVAC service professionals cleaning straight, internally enhanced ferrous and nonferrous tubes. It helps remove soft, light scale deposits from tube...
-
Enhanced Tube Cleaning Brush for 5/8 in. ID Tubes, 15-Pack
Our Price:$149.94This dual-diameter tube cleaning brush is for HVAC service professionals cleaning internally enhanced or spiraled 5/8 in. ID tubes. It helps remove soft, light scale deposits from straight ferrous...
HVAC Controls, Parts & Service: Everything You Need to Keep Your System Running
Whether you're replacing a worn component, upgrading system controls, or performing routine maintenance, this category covers the essential parts and equipment that keep heating and cooling systems operating efficiently. Use the subcategory paths below to find exactly what your job requires.
Choose your starting point
Popular examples in this category
Keeping HVAC Systems Operational and Efficient
These products support repair, maintenance, and replacement tasks across residential and commercial HVAC systems. From failed capacitors to worn pump bearings, having the right part on hand reduces downtime, restores comfort, and extends the working life of heating and cooling equipment.
Start With the System and the Problem
Identify the system type (hydronic, forced air, refrigeration), the failing or worn component, and the specifications required—voltage, flow rate, pressure rating, or physical dimensions. Matching specs precisely prevents compatibility issues and callbacks on completed jobs.
Where These Parts and Controls Are Used
Common applications include boiler and hydronic heating systems, split and packaged air conditioning units, commercial refrigeration, and ventilation systems. Parts like circulator pumps, capacitors, and aquastats are used in both new installations and service replacement scenarios.
Sourcing Tips and Service Considerations
Always verify OEM specifications or cross-reference part numbers before ordering. For service work, stocking common failure items—capacitors, condensate pumps, and bearings—reduces truck rolls and speeds up repairs. Cleaning equipment supports preventive maintenance programs that lower long-term service costs.
Which Subcategory Do You Need? A Quick Reference
Match your service need to the right subcategory path using this guide.
| Need | Best Fit Subcategory | Why It Matters |
|---|---|---|
| Control boiler water temperature | Aquastats | Aquastats regulate when the boiler fires based on water temperature setpoints, protecting the system and maintaining efficiency |
| Replace a failed motor or pump component | Bearings or Circulator Pump Accessories | Bearings and accessories allow targeted repair without full pump replacement, saving cost and labor time |
| Restore circulation in a hydronic system | Circulator Pumps | The right pump must match system flow rate and head pressure to maintain proper heat distribution |
| Fix a non-starting AC or refrigeration unit | Capacitors or Compressors | Capacitors are a common low-cost fix; if the compressor itself has failed, replacement is required |
| Remove standing water from drain pans | Condensate Pumps | Condensate pumps prevent water damage and mold by actively removing condensate when gravity drainage isn't available |
| Perform seasonal system cleaning | HVAC Cleaning Equipment | Regular coil and drain cleaning maintains airflow, efficiency, and indoor air quality across all system types |
Plan the right fit before choosing
Step 1: Identify the System and Failure Point
Before selecting any part or control, confirm the system type and the specific component that needs attention. Hydronic systems rely heavily on circulator pumps, aquastats, and bearings, while refrigerant-based systems commonly require capacitors and compressors.
- Note the system voltage, BTU capacity, and fluid or refrigerant type
- Check whether the failure is electrical, mechanical, or related to flow and pressure
- Confirm whether you need an exact replacement or an equivalent cross-reference
Step 2: Match Specifications to the Application
Each subcategory has critical spec requirements. Capacitors must match microfarad and voltage ratings. Circulator pumps require correct flow rate and head pressure. Aquastats need the right temperature range for the system they control.
- Use the existing part number or equipment nameplate data as your starting point
- For pumps and compressors, verify flange size, port configuration, and mounting style
- For controls like aquastats, confirm setpoint range and differential settings
Step 3: Plan for Preventive Maintenance
Many service calls can be reduced by stocking high-failure-rate components and scheduling regular cleaning and inspection. HVAC cleaning equipment and condensate pump maintenance are often overlooked until a system failure occurs.
- Stock capacitors and condensate pumps as common wear items for service vans
- Schedule coil and drain line cleaning seasonally to prevent efficiency loss
- Inspect bearings and pump accessories annually in hydronic systems
From aquastats to compressors, each subcategory focuses on a specific part or function so you can navigate directly to what you need.
Most HVAC service calls involve either an electrical component failure (capacitor, control) or a mechanical one (bearing, pump, compressor), and this category covers both.
Parts and controls in this category are used across light residential systems, large commercial HVAC installations, and industrial climate control applications.
Whether you're responding to a breakdown or running a scheduled maintenance program, this category includes parts and equipment for both approaches.
Common questions before buying
How do I know if I need a capacitor or a compressor replacement?
Start with the capacitor—it's a common, low-cost failure point that can prevent a compressor from starting. Test the capacitor first. If it checks out and the compressor still won't run, further diagnosis of the compressor is warranted.
What specifications do I need to replace a circulator pump?
You'll need the flow rate (GPM), head pressure (feet of head), pipe connection size, and voltage. Check the nameplate on the existing pump or the system design documents to confirm these values before ordering.
Can I use HVAC cleaning equipment on both residential and commercial systems?
Yes, but verify that the equipment capacity and chemical compatibility match the system size and coil material. Some commercial systems require higher-pressure coil cleaning tools than those used in residential applications.
What is an aquastat and when does it need to be replaced?
An aquastat is a temperature control device used in hydronic heating systems to regulate boiler operation. It may need replacement if the system short-cycles, fails to reach setpoint, or if the control shows signs of electrical failure during testing.
High-Limit Oil Aquastat Relay, 120VWBB394547
Bluetooth Circulator Pump Communication ModuleWBB1529849
Industrial Plug-In Temperature Controller with Power Cord, 40° to 110°FWBB970415
Clear Plastic Thermostat GuardWBB860061